============================================================================================================================== Filename: BMC_X12AST2600-ROT-5201MS_20231220_01.03.11_STDsp.bin version:01.03.11 BuildDate: 2023-12-20 U-Boot baseline : 2019.04 Java SOL Viewer version : v0.5.16 Java iKVM Viewer version : v1.69.53 Redfish API : Redfish_1_11_API_full_list_20231003 TEE Package dateCode: 20210911 pooh.ko: 3.0.5 tee.bin: 0000.00.29 antiRBID: 0x0001 RNDIS|CDC-ECM: RNDIS and CDC-ECM Supported MBs: X12DPI-6, X12DPU-6, X12DDW-A6, X12DPG-QT6, X12DHM, X12DPFR-AN6, X12DAI-N6, X12DPG-AR6, X12DPG-U6, X12DPL-I6, X12DSC-A6 X12SPW-TF/-F, X12SPi-TF, X12SPO-F/-NTF, X12SPZ-SPLN6F, X12SPM-TF/-LN4F/-LN6TF, X12SPL-F/-LN4F, X12SPED-F, X12DPG-QBT6 1. Category: Fix Description: [167662] ECO -- 18379 -- 01.03.00(12/01/2023) -- Dynamic DNS is able to save setting when 'BMC Hostname' is empty [167591] ECO -- 16914 -- 01.03.10(20231203) -- Dynamic DNS is able to save setting when 'BMC Hostname' is empty Impact motherboard: X12DPI, X12SPi Affected functions: Validation: 1. Login webgui 2. Switch 'Dynamic Update Enable' to 'ON' 3. Empty 'BMC Hostname' 4. Press button 'Save' 2. Category: Fix Description: [165157] STD -- 22739 -- 01.01.02 (2023/10/16) -- Fix Fail point 1: After BMC change to DHCPv6 Stateful mode, DHCPv6 Stateless IP still can connect. SPEC define: When BMC is switched from DHCPv6 Stateless mode to DHCPv6 Stateful mode in WebUI, BMC should assign its BMC IP to new IP and remove its previous IPv6 IP. Impact motherboard: X12DPI Affected functions: Validation: 1. Login web with ADMIN. 2. Configuration → Network → IPv6 → Turn on IPv6 3. Choose Auto Configuration → DHCPv6 Stateless → Press "Save" to save network settings 4. Check IPv6Addresses of Redfish path redfish/v1/Managers/1/EthernetInterfaces/1 a. There is an entry of AddressOrigin is SLAAC. 5. Login web with ADMIN. 6. Configuration → Network → IPv6 → Turn on IPv6 7. Choose Auto Configuration → DHCPv6 Stateful → Press "Save" to save network settings 8. Check IPv6Addresses of Redfish path redfish/v1/Managers/1/EthernetInterfaces/1 a. There is an entry of AddressOrigin is DHCPv6 when DHCPv6 server assigned IP to BMC. b. There is no entry of AddressOrigin is SLAAC because BMC set IPv6AutoConfigEnabled false.(Fail point 1) 3. Category: Fix Description: [167404] ECO -- 20122 -- 01.03.04(2023/10/17) -- Sensor Naming -- VRMCpu sensor doesn't match with spec [156300] ECO -- 20122 -- 01.13.10(20230320) -- WebGUI -- Sensor naming doesn't match the spec. Impact motherboard: X12STD-F,X12STL-IF Affected functions: Validation : 1. follow Supermicro_BMC_Sensor_Naming_Guildeline 4. Category: Fix Description: [167339] ECO -- 20899 -- 01.01.08(2023/11/15) -- Web Function -- MEL show incorrect format when type long input of remote User/remote group at LDAP & AD [164786] STD -- SW-- 01.03.03--Wording issue after seting AD remote group with more characters [162524] ECO — 22715 — 01.01.17(09/04/2023) — [Function] MEL show incorrect format when type long input of remote User/remote group at LDAP & AD. [162259] ECO -- 21603 -- 01.01.03 -- MEL not match with SPEC with long input of remote User/remote group [162055] ECO -- 18380 -- 01.01.16(2023/07/26) -- WEB -- MEL show incorrect format when type long input of remote User/remote group at LDAP & ADECO -- 16914 -- 01.01.48(08/11/2023) -- MEL show incorrect format when type long input of remote User/remote group at LDAP & AD [162770] ECO -- 18380 -- 01.01.16(2023/07/26) -- WEB -- MEL show incorrect format when type long input of remote User/remote group at LDAP & AD [162299] ECO -- 16914 -- 01.03.05(20230904) -- MEL show incorrect format when type long input of remote User/remote group at LDAP & AD. Impact motherboard: X12DPI Affected functions: Validation : 1. format/wording should displayed well 5. Category: Fix Description: [166292] CPLD icon no index under update page Impact motherboard: X12DPI Affected functions: Validation: 1. Go to Maintenance - Firmware Management - Update page. 2. Click CPLD MB 2 should have index. Eg. CPLD1 Motherboard 6. Category: Fix Description: [167499] ECO -- 16914 -- 01.03.10(2023/12/03) -- Web -- Both DNS Lookup and Static address can be modified at the same time Impact motherboard: X12DPI, X12SPi Affected functions: Validation: 1. Login webgui 2. Enter to Directory Services page and toggle on Active Directory 3. Add 1 address on both DNS Lookup and Static fields 4. Add 2nd address on DNS Lookup field, observe if edit and delete icons appear on Static field 5. Add 2nd address on Static field, observe if edit and delete icons appear on DNS Lookup field 7. Category: Fix Description: [167452] STD -- SW-- 01.01.08 -- No" AuthFailureLoggingThreshold" option for Advanced Settings of Users Impact motherboard: X12DPI Affected functions: Validation: 1. Login webgui 2. Go Users 3. Expand Advanced Settings 4. Change "Failed Login Attempt Lockout Threshold" from default setting 3 to 0 5. Check MEL 8. Category: Fix Description: [159807] ECO -- 16914 -- 01.03.03(07/14/2023) -- Web does not show any LLDP information after enable LLDP Impact motherboard: X12DPI, X12SPI Affected functions: Validation: 1. Login WEB GUI and change page to Configuration -> Network -> LLDP 2. Switch 'Enable LLDP' to 'ON' 3. Press down button 'Save' 4. Check the all information at LLDP Receive area 9. Category: Fix Description: [167456] STD -- SW-- 01.01.08 -- Misspelled words on MEL page Impact motherboard: X12DPI Affected functions: Validation: 1. Login web with ADMIN. 2. Go to SMTP page and input a value into [User Name], MEL should be "[MEL-0140] SMTP User Name test.. was configured successfully." 10. Category: Fix Description: [167269] [16728 -- ECO -- 01.03.09] ADMIN username still appears with two spaces in the SMCIPMITool MEL Impact motherboard: X12DPI, X12DPFR Affected functions: Validation: 1. Login ADMIN account in WEB GUI with wrong password three times for locking 2. Login ADMIN account in WEB GUI with PWD 3. Login ADMIN account in WEB GUI again 4. Check MEL by WEB: Maintenance-> Maintenance Event Log 5. Check MEL by smcipmitool: mel list 11. Category: Fix Description: [166251] STD -- 21386 -- 01.01.03 (2023/11/03) -- Fail to get correct DNS values using SMCIPMITool raw commands. Impact motherboard: X12DPI Affected functions: Validation: 1. Login web with ADMIN. 2. Configuration → Network → IPv4 → Advanced Settings 3. Choose Manually obtain DNS server IP → Press "Save" to save network settings 4. Send raw commands to get DNS values for ipv4 using SMCIPMITool 5. Get ipv4 DNS1 value using "ipmi raw 30 68 0a 00 00" 6. Get ipv4 DNS2 value using "ipmi raw 30 68 0a 02 00" 12. Category: Fix Description: [167025] [SYS-531A-I] BMC "sensor" page information is incorrect with BMC FW: 01.01.24 [167032] [SYS-551A-T] BMC "sensor" page information is incorrect with BMC FW: 01.01.24 (similar as #167025) Impact motherboard: X12DPI Affected functions: Validation: 1. Go to Dashboard page. 2. Click Sensor Readings. 3. Check Sensor page layout should display correctly. 13. Category: Fixed Description: [166422] [IPMI 01.01.24 ECO] LAB SMSTC IPMI ECO automation test fail Impact motherboard: X12DPI Affected functions: Validation: 1. Run IPMI ECO automation and check test result. 14. Category: Enhancement Description: [166696] GPU "Unknown Slot 1(1)" issue on SYS-621C-TN12R (Mother board MBD-X13DDW-A-P) Impact motherboard: X12DPI Affected functions: Validation: 15. Category: Fix Description: [165011] ECO -- 23439 -- 01.00.03 (2023/10/15) -- WEB -- MEL Log msg is incorrect when configure Syslog. Impact motherboard: X12DPI Affected functions: Validation: 1. Factory default - Reset BMC to default. 2. WebGUI -> Configuration -> Notifications -> Syslog. 3. Modify the configurations of Syslog and Save. 4. WebGUI -> Maintenance -> Maintenance Event Log. 5. Check if the behavior of MEL is correct or not. Protection maps: X12DAI-N6-20220614-152047.bin X12DDW-20200618-150509.bin X12DHM-20220912-161301.bin X12DPFR-AN6-20201110-171036.bin X12DPG-AR6-20220616-170358.bin X12DPG-QBT6.bin X12DPG-QT6.bin X12DPG-U6.bin X12DPi-20230222-165258.bin X12DPL.bin X12DPU-20220912-161301.bin X12DSC-A6.bin X12SPED.bin X12SPI-TF-20220615-135812.bin X12SPL-F(-LN4F)-20220615-105913.bin X12SPM.bin X12SPO.bin X12SPW-F(-TF)-20220629-142628.bin X12SPZ.bin ============================================================================================================================== Filename: BMC_X12AST2600-ROT-5201MS_20231203_01.03.10_STDsp.bin version:01.03.10 BuildDate: 2023-12-03 U-Boot baseline : 2019.04 Java SOL Viewer version : v0.5.16 Java iKVM Viewer version : v1.69.53 Redfish API : Redfish_1_11_API_full_list_20231003 TEE Package dateCode: 20210911 pooh.ko: 3.0.5 tee.bin: 0000.00.29 antiRBID: 0x0001 RNDIS|CDC-ECM: RNDIS and CDC-ECM Supported MBs: X12DPI-6, X12DPU-6, X12DDW-A6, X12DPG-QT6, X12DHM, X12DPFR-AN6, X12DAI-N6, X12DPG-AR6, X12DPG-U6, X12DPL-I6, X12DSC-A6 X12SPW-TF/-F, X12SPi-TF, X12SPO-F/-NTF, X12SPZ-SPLN6F, X12SPM-TF/-LN4F/-LN6TF, X12SPL-F/-LN4F, X12SPED-F, X12DPG-QBT6 1. Category: Fix Description: [159052] ECO -- 21386 -- 01.00.18 (2023/06/27) -- MEL Log msg is incorrect when ONLY enable/disable Radius. Impact motherboard: X12SPW Affected functions: Validation: 1. Login web with ADMIN. 2. Configuration → Account Services → Directory Service → Enable LDAP 3. Enable Activate Directory → Press "OK" to disable LDAP 4. Enable Radius → Press "OK" to disable Activate Directory 5. Enable LDAP → Press "OK" to disable Radius 6. Disable LDAP 2. Category: Fix Description: [166555] ECO -- 21603 -- 01.01.10(20231108) -- supposed to show ONLY the least required key of the limited function when no License is activated Impact motherboard: X12SPW Affected functions: Validation: 1. Go to Configuration - Account Services - Directory Service page. 2. Go to Configuration - Notifications - Alerts page. 3. Check hint should only show minimum license requirement. 3. Category: Fix Description: [166802] ECO -- 16914 -- 01.03.09(2023/11/10) -- DNS Lookup toggle button and Host interface radio buttons aren't disabled when system lockdown mode is on Impact motherboard: X12DPL, X12SPW Affected functions: Validation: 1. Turn on System lockdown mode 2. Enter to Directory Services pages and expand Active Directory area 3. Enter to Host interface page and check radio buttons 4. Category: Fix Description: [166554] ECO -- 21603 -- 01.01.10(20231108) -- License require pop-up diagram not quite match with definition (string of the button) [162319] ECO -- 16914 -- 01.03.05(2023/09/04) -- Web UI -- After selecting "Backup Existing BIOS Image", a confirmation prompt not appear before BIOS firmware update [159596] ECO -- 20899 -- 01.00.58 -- Enable and Disable SNMP modal buttons show Close and Save instead of Yes and No [155310] ECO -- 16914 -- 01.01.41 -- At License Activation popup window Are you sure you want to ACTIVATE the License? Buttons are Close and Save instead of Yes and No Impact motherboard: X12SPM, X12DDW, X12SPW Affected functions: Validation: 1.1 Remove license 1.2 Go to Configuration - Notifications - Syslog page. 1.3 Go to Configuration - BMC Settings - System Lockdown page. 1.4 Go to Maintenance - Troubleshooting - Console Capture page. 1.5 Check pop-up button names. 2.1 Go to Maintenance - Firmware Management - Update page. 2.2 Go to Configuration - Notifications - SNMP page. 2.3 Go to Maintenance - License Management page. 2.4 Check pop-up button names. 5. Category: Fix Description: [164539] ECO -- 16914 -- 01.03.07(09/29/2023) -- Host Interface only support RNDIS at release note and help page but web appear CDC-ECM and RNDIS Impact motherboard: X12DPU-6, X12SPW Affected functions: Help page Validation: 1. Login Web GUI and change path to Configuration -> BMC Settings -> Host Interface 2. Check 'USB connection' 3. Check the help page content of Host Interface 6. Category: Fix Description: [164293] ECO — 21386 — 01.00.26(09/26/2023) — [MEL] — Non-set IPv4 DNS Server IP related MEL should not be shown when setup Hostname. Impact motherboard: X12SPW Affected functions: Validation: 1. Login BMC Web 2. Setup Hostname in Configuration-> Network-> General-> Hostname, then press 'Save' button 3. Check Hostname is saved 4. Check MEL in Maintenance-> Maintenance Event Log 5. clear Hostname in Configuration-> Network-> General-> Hostname, then press 'Save' button 6. Check Hostname is saved 7. Check MEL in Maintenance-> Maintenance Event Log 7. Category: Fix Description: [164286] STD -- SW-- 01.01.05-- Host Interface page can be configurated in system lockdown mode or login with User privilege Impact motherboard: X12SPW Affected functions: Validation: 1. Login webgui 2. Turn on system lockdown mode 3. Go to Host Interface page 8. Category: Fix Description: [165603] STD -- SW-- 01.00.30--No related mel generated after SMTP sender's address is removed Impact motherboard: X12SPW Affected functions: Validation: 1. Login WEB GUI 2. Go to SMTP page 3. Fill in a sender's address, Save 4. Remove sender's address, Save 5. Check MEL page 9. Category: Fix Description: [165364] ECO -- 16914 -- 01.03.08(20231017) -- SMCIPMITool -- [MEL-0000]/[MEL-0002] has 2 spaces before the User Name Impact motherboard: X12SPI, X12SPW Affected functions: Validation: 1. Login WEB GUI 2. Add new User by WEB: Configuration-> Account Services-> User (User Name: User3), then 'Save' 3. Check Add successfully 4. Edit the new added user by WEB, press the Edit(pancil icon) with 'User3', change User Name to User33, then 'Save' 5. Check Edit successfully 6. Check MEL by WEB: Maintenance-> Maintenance Event Log 7. Check MEL by smcipmitool: mel list 10. Category: Fix Description: [165307] STD -- SW-- 01.01.09--No mel generated when changing Prefix length from 128 to 32 Impact motherboard: X12SPW Affected functions: Validation: 1. Login webgui 2. Go to IP Access Control on Network page 3. Enable IP Access Control 4. Add a Rule 5. Fill in IP Address 6. Set Prefix Length to 128, Save 7. Modify Prefix Length to 32, Save 8. Check MEL 11. Category: Fix Description: [165361] ECO -- 16914 -- 01.03.08(20231017) -- [GUI] Able to add ACCEPT/DROP rules with duplicate IP Address/Mask Impact motherboard: X12SPI, X12SPW Affected functions: Validation: 1. Login BMC Web 2. Add ACCEPT 10.122.133.144/32, Save 3. Add another ACCEPT 10.122.133.144/32, Save 4. Add DROP 10.122.133.144/32, Save 5. Add another DROP 10.122.133.144/32, Save 12. Category: Fix Description: SOL hang/stuck issue Impact motherboard: X12SPW Affected functions: Validation: 1. ssh user-name@BMCIP 2. cd system1/sol1 3. start 4. run some command 5. press enter, esc and T in sequence to exit 6. exit (For more info, please consult Peter Chiang) Protection maps: X12DAI-N6-20220614-152047.bin X12DDW-20200618-150509.bin X12DHM-20220912-161301.bin X12DPFR-AN6-20201110-171036.bin X12DPG-AR6-20220616-170358.bin X12DPG-QBT6.bin X12DPG-QT6.bin X12DPG-U6.bin X12DPi-20230222-165258.bin X12DPL.bin X12DPU-20220912-161301.bin X12DSC-A6.bin X12SPED.bin X12SPI-TF-20220615-135812.bin X12SPL-F(-LN4F)-20220615-105913.bin X12SPM.bin X12SPO.bin X12SPW-F(-TF)-20220629-142628.bin X12SPZ.bin ============================================================================================================================== Filename: BMC_X12AST2600-ROT-5201MS_20231110_01.03.09_STDsp.bin version:01.03.09 BuildDate: 2023-11-10 U-Boot baseline : 2019.04 Java SOL Viewer version : v0.5.16 Java iKVM Viewer version : v1.69.53 Redfish API : Redfish_1_11_API_full_list_20231003 TEE Package dateCode: 20210911 pooh.ko: 3.0.5 tee.bin: 0000.00.29 antiRBID: 0x0001 RNDIS|CDC-ECM: RNDIS and CDC-ECM Supported MBs: X12DPI-6, X12DPU-6, X12DDW-A6, X12DPG-QT6, X12DHM, X12DPFR-AN6, X12DAI-N6, X12DPG-AR6, X12DPG-U6, X12DPL-I6, X12DSC-A6 X12SPW-TF/-F, X12SPi-TF, X12SPO-F/-NTF, X12SPZ-SPLN6F, X12SPM-TF/-LN4F/-LN6TF, X12SPL-F/-LN4F, X12SPED-F, X12DPG-QBT6 1. Category: Fix Description: [165575] ECO -- 18380 -- 01.00.19 -- After Web BMC Update, MEL Maintenance Event Log does not contain entry stating that BMC firmware was updated successfully. Impact motherboard: X12SPW Affected functions: Validation: After the BMC update is completed, MEL pops up "BMC firmware was updated successfully". 2. Category: Fix Description: [164913][SYS-510P-WTR_MP_H1_729]Slot number not match spec under BMC Web GUI Impact motherboard: X12SPW, with all possible RSC configurations. For example: + RSC-W-66G4, RSC_WR_6 + RSC-W2-66G4, RSC-W2R-88G4 + RSC-W2-688G4, RSC-W2R-88G4 + RSC-W2-8888G4, RSC-W2R-88G4 Affected functions: Validation: 1. Login in Web With ADMIN 2. Sensor Readings 3. Check AOC_NIC Temp numbering name in Sensor Readings in Sensor session 4. Go to Network AOC 5. Check Network AOC Location as System Slot number 3. Category: Fix Description: [161863] ECO -- 16914 -- 01.01.44 -- SUM Test case fails: 0030 - Ping BMC IP from SUT with different LAN interface. Impact motherboard: All X12 MBs Affected functions: Validation: 1. Run the case. 4. Category: Fix Description: [163120] The Severity display with improper Blue color code happened for MEL "ejected unsuccessfully" Impact motherboard: X12DPU supports NVMe drive Affected functions: Validation: 1. Go to System - Storage Monitoring - Physical View page. 2. Select NVMe drive and perform Eject action. 3. Check [MEL-0128] severity should change to Wanring. 5. Category: Fix Description: [165357] ECO -- 16914 -- 01.03.08(20231017) -- [GUI] Fail to delete Active Directory Domain Name [165360] ECO -- 16914 -- 01.03.08(20231017) -- [GUI] Fail to edit/delete Active Directory Server Address Impact motherboard: X12SPI, X12SPW Affected functions: Validation: 1. Setup Active Directory in WEB: Configuration-> Account Services-> Directory Service 2. Enable Active Directory, set to 'ON' 3. Enable DNS Lookup, set to 'ON' 4. Add invalid Domain Name: satc.com, then 'Submit' 5. Add valid Domain Name: google.com, then 'Submit' 6. Try to delete Domain 'satc.com', press trash can then 'Submit' 7. Try to delete Domain 'google.com', press trash can then 'Submit' 6. Category: Fix Description: [165078] ECO -- 16914 -- 01.03.08(20231017) -- Web function -- The tips of Remote User and Remote Group are different from the spec Impact motherboard: X12SPL, X12SPW Affected functions: Validation: 1. Login the Web, go to the Directory Service page (Configuration > Account Services page > Directory Service) 2. Select LDAP switch to enable 3. Select "Add" button in Rules section 4. Directly press the "Save" button without filling in the values 5. It will show the tips 7. Category: Fix Description: [165364] ECO -- 16914 -- 01.03.08(20231017) -- SMCIPMITool -- [MEL-0000]/[MEL-0002] has 2 spaces before the User Name Impact motherboard: X12SPI, X12SPW Affected functions: Validation: 1. Login webgui 2. Add new User by WEB: Configuration-> Account Services-> User (User Name: User3), then 'Save' 3. Check Add successfully 4. Edit the new added user by WEB, press the Edit(pancil icon) with 'User3', change User Name to User33, then 'Save' 5. Check Edit successfully 6. Check MEL by WEB: Maintenance-> Maintenance Event Log 7. Check MEL by smcipmitool: mel list 8. Category: Fix Description: [161107] ECO -- 16914 -- 01.03.04 (2023/08/17) -- WEB -- Need to define MEL-ID for modified IPv6 address/Prefix Length. Impact motherboard: X12DPU, X12SPW Affected functions: Validation: 1. Login web with ADMIN. 2. Configuration → Network → IPv6 → Select "Static Configuration" → Input string into "IPv6 Address", "Prefix Length", "Gateway IP" → Press "Save" 3. Maintenance → Maintenance Event Log → Check MEL is general 4. Configuration → Network → IPv6 → Modified "IPv6 Address" 5. Maintenance → Maintenance Event Log → Check MEL is general (Pic 1) 6. Configuration → Network → IPv6 → Modified "Prefix Length" 7. Maintenance → Maintenance Event Log → Check MEL is general (Pic 2) 9. Category: Fixed Description: ECO -- 16914 -- 01.03.03(07/14/2023) -- GUI -- No LLDP introduction at Help page Impact motherboard: X12SPW Affected functions: Validation: Check in Help page 10. Category: Fix Description: [164365] BMC 01.03.07 Duplicate MEL message when enabling IPv6 in WebGUI Impact motherboard: X12DPU, X12SPW Affected functions: Validation: 1. Login the Web, go to the Network page (Configuration > Network) 2. System would not generate duplicate message for "[MEL-0256] IPv6 gateway was configured to 2001::1234:1:aaaa successfully." 11. Category: Fix Description: [164718] ECO -- 18380 -- 01.02.00 -- iKVM Reset modal buttons show "Close" and "OK" instead of Yes and No even though it asks "Are you sure you want to RESET the iKVM?" Impact motherboard: X12SPW Affected functions: Remote Control Validation: 1.Go to Configuration > Remote Control > IKVM Reset 2.Click Reset button 3.The text displayed on the buttons will be [Cancel] and [Reset] 12. Category: Fix Description: [164716] ECO -- 18380 -- 01.02.00 -- Faulty message "Please enable one directory service at a time !" should remove the extra space. Impact motherboard: X12SPW Affected functions: Validation: 1. Go to Configuration - Account Services - Directory Service page. 2. Check hint message which is removed the extra space. 13. Category: Fix Description: [164331] ECO -- 16914 -- 01.03.07(2023/09/29) -- Web -- Fail to delete the search base in the LDAP Configuration [164427] ECO -- 16416 -- 01.03.03(2023/10/06) -- Web -- Search base display ISNULL after the data has removed Impact motherboard: X12SPO, X12SPW Affected functions: Validation: 1. Login the Web, go to the Directory Service page (Configuration > Account Services page > Directory Service) 2. Select LDAP switch to enable 3. Select "Add" in the Search Base field and typing "dc=ad,dc=satc,dc=com" then press Save button 4. Press "Submit" 5. Select "Delete" icon to delete the Search Base then press "Submit" Protection maps: X12DAI-N6-20220614-152047.bin X12DDW-20200618-150509.bin X12DHM-20220912-161301.bin X12DPFR-AN6-20201110-171036.bin X12DPG-AR6-20220616-170358.bin X12DPG-QBT6.bin X12DPG-QT6.bin X12DPG-U6.bin X12DPi-20230222-165258.bin X12DPL.bin X12DPU-20220912-161301.bin X12DSC-A6.bin X12SPED.bin X12SPI-TF-20220615-135812.bin X12SPL-F(-LN4F)-20220615-105913.bin X12SPM.bin X12SPO.bin X12SPW-F(-TF)-20220629-142628.bin X12SPZ.bin ============================================================================================================================== Filename: BMC_X12AST2600-ROT-5201MS_20231017_01.03.08_STDsp.bin version:01.03.08 BuildDate: 2023-10-17 U-Boot baseline : 2019.04 Java SOL Viewer version : v0.5.16 Java iKVM Viewer version : v1.69.53 Redfish API : Redfish_1_11_API_full_list_20231003 TEE Package dateCode: 20210911 pooh.ko: 3.0.5 tee.bin: 0000.00.29 antiRBID: 0x0001 RNDIS|CDC-ECM: RNDIS and CDC-ECM Supported MBs: X12DPI-6, X12DPU-6, X12DDW-A6, X12DPG-QT6, X12DHM, X12DPFR-AN6, X12DAI-N6, X12DPG-AR6, X12DPG-U6, X12DPL-I6, X12DSC-A6 X12SPW-TF/-F, X12SPi-TF, X12SPO-F/-NTF, X12SPZ-SPLN6F, X12SPM-TF/-LN4F/-LN6TF, X12SPL-F/-LN4F, X12SPED-F, X12DPG-QBT6 1. Category: Fix Description: [164419] ECO -- 16416 -- 01.03.03(2023/10/06) -- Web -- Adding rules with Empty Remote User and Remote Group in LDAP & AD shows incorrect tips "LANG_CONFIG_AD_DNS_CTRL_ADDR" Impact motherboard: X12DDW Affected functions: Validation: 1. Go to Configuration - Account Services - Directory Service page. 2. Turn on LDAP and add rules of LDAP. 3. Check error message should be shown correctly. 2. Category: Enhancement Description: [164440] BMC:01.00.12 does not support IPMI temperature sensor reading of AOC-LPE32002-M2 [164133] BMC:01.00.12 does not support IPMI temperature sensor reading of AOC-LPE35002-M2 [161980] AOC-QLE2692SR don't have temperature in IPMI Impact motherboard: X12DSC-A6 Affected functions: Validation: 1.Insert Emulex and Qlogic fiber channel device to MB 2.Check the Network AOC page and Sensor page 3. Category: Fix Description: [164404] [IPMI ECO 01.03.07] UID LED should be blinking but keep solid on when use WebUI UID Control Impact motherboard: All X12 MBs Affected functions: Validation: 1. Login webgui 2. Check UID LED should be blinking but keep solid on when use WebUI UID Control 4. Category: Fix Description: [164236] STD -- SW-- 01.01.05-- "Verify SSL Certificate" and " Accept Self-signed Certificate" shouldn't be selected if setting File Server to http://xxxxx Impact motherboard: X12DDW Affected functions: Virtual Media Validation: 1.Go to Virtaul Media and Edit VM Connection 2.Set File Server to "https://xxxxxx" and click Save button 3.Edit the added VM Connection 4.Change file server from "https://xxxx" to "http://xxxxx" and click Save button 5.Check the data of Verify SSL Certificate and Accept Self-signed Certificate 5. Category: new Description: [157723] IPMI missing BPN CPLD update option Impact motherboard: X12DHM-6 Affected functions: Validation: 1. Login webgui 2. Go to Firmware Update page 4. Check BPN CPLD update option 6. Category: Fix Description: [160930] STD -- SW-- 01.00.22--No MEL generated after SNMPv2 is disabled Impact motherboard: X12DDW Affected functions: Validation: 1. Login webgui 2. Go to SNMP page 3. Enable SNMPv2 and then Disable it 4. Check MEL page 7. Category: Fix Description: [163386] [SCC_v3.1.3_b230919] The MaxSpeedMHz isn’t listed in the Redfish URI “/redfish/v1/Systems/1/Processors/1,” resulting in the loss of Frequency Capacity data. Impact motherboard: X13DDW Affected functions: Validation: 1. Get Redfish URI "/redfish/v1/Systems/1/Processors/1," 2. Check [MaxSpeedMHz] 8. Category: Fix Description: [152262] ECO -- 21386 -- 01.01.08 -- [WEB] Not defined page shown in WEB (License Activation-> CPU) Impact motherboard: X12DDW Affected functions: Validation: 1. Login BMC Web. 2. web GUI-> Maintainance-> License Activation Protection maps: X12DAI-N6-20220614-152047.bin X12DDW-20200618-150509.bin X12DHM-20220912-161301.bin X12DPFR-AN6-20201110-171036.bin X12DPG-AR6-20220616-170358.bin X12DPG-QBT6.bin X12DPG-QT6.bin X12DPG-U6.bin X12DPi-20230222-165258.bin X12DPL.bin X12DPU-20220912-161301.bin X12DSC-A6.bin X12SPED.bin X12SPI-TF-20220615-135812.bin X12SPL-F(-LN4F)-20220615-105913.bin X12SPM.bin X12SPO.bin X12SPW-F(-TF)-20220629-142628.bin X12SPZ.bin ============================================================================================================================== Filename: BMC_X12AST2600-ROT-5201MS_20230929_01.03.07_STDsp.bin version:01.03.07 BuildDate: 2023-09-29 U-Boot baseline : 2019.04 Java SOL Viewer version : v0.5.16 Java iKVM Viewer version : v1.69.53 Redfish API : Redfish_1_11_API_full_list_20230824 TEE Package dateCode: 20210911 pooh.ko: 3.0.5 tee.bin: 0000.00.29 antiRBID: 0x0001 RNDIS|CDC-ECM: RNDIS only Supported MBs: X12DPI-6, X12DPU-6, X12DDW-A6, X12DPG-QT6, X12DHM, X12DPFR-AN6, X12DAI-N6, X12DPG-AR6, X12DPG-U6, X12DPL-I6, X12DSC-A6 X12SPW-TF/-F, X12SPi-TF, X12SPO-F/-NTF, X12SPZ-SPLN6F, X12SPM-TF/-LN4F/-LN6TF, X12SPL-F/-LN4F, X12SPED-F, X12DPG-QBT6 1. Category: Fix Description: [150506] ECO --16914 -- 01.01.34 (2022/11/05) -- WEB -- Invalid Sensor Impact motherboard: X12SPW Affected functions: Validation: 1. webGUI -> Sensor Readings. Exanmine the sensor name of DIMM and PMEM. 2. Category: Fix Description: Fix fanFAIL feature broken from 01.03.01 to 01.03.06. Impact motherboard: All X12 MBs Affected functions: Validation : 1. Remove one of the fans, it should trigger fanFAIL behavior 2. Plug the fan, the system should resume to normal. Protection maps: X12DAI-N6-20220614-152047.bin X12DDW-20200618-150509.bin X12DHM-20220912-161301.bin X12DPFR-AN6-20201110-171036.bin X12DPG-AR6-20220616-170358.bin X12DPG-QBT6.bin X12DPG-QT6.bin X12DPG-U6.bin X12DPi-20230222-165258.bin X12DPL.bin X12DPU-20220912-161301.bin X12DSC-A6.bin X12SPED.bin X12SPI-TF-20220615-135812.bin X12SPL-F(-LN4F)-20220615-105913.bin X12SPM.bin X12SPO.bin X12SPW-F(-TF)-20220629-142628.bin X12SPZ.bin ============================================================================================================================== Filename: BMC_X12AST2600-ROT-5201MS_20230928_01.03.06_STDsp.bin version:01.03.06 BuildDate: 2023-09-28 U-Boot baseline : 2019.04 Java SOL Viewer version : v0.5.16 Java iKVM Viewer version : v1.69.53 Redfish API : Redfish_1_11_API_full_list_20230824 TEE Package dateCode: 20210911 pooh.ko: 3.0.5 tee.bin: 0000.00.29 antiRBID: 0x0001 RNDIS|CDC-ECM: RNDIS only Supported MBs: X12DPI-6, X12DPU-6, X12DDW-A6, X12DPG-QT6, X12DHM, X12DPFR-AN6, X12DAI-N6, X12DPG-AR6, X12DPG-U6, X12DPL-I6, X12DSC-A6 X12SPW-TF/-F, X12SPi-TF, X12SPO-F/-NTF, X12SPZ-SPLN6F, X12SPM-TF/-LN4F/-LN6TF, X12SPL-F/-LN4F, X12SPED-F, X12DPG-QBT6 1. Category: Fix Description: [162699] [IPMI ECO][01.01.23] SMSTC automation test results Fail.(timezone +0930 config fail) Impact motherboard: X12SPO, X12DPU Affected functions: Validation: 1. Check timezone "+0930" can be setup. ipmitool -H -U -P raw 0x30 0x68 0x01 0x01 0x00 0x01 0x2B 0x30 0x39 0x33 0x30 0x01 2. Category: Fix Description: [163529] ECO — 21603 — 01.01.07(09/22/2023) — [MEL] — No related MEL when disable TSIG Authentication. Impact motherboard: X12SPO, X12DPU Affected functions: Validation: 1. Login BMC Web. 2. Configuration -> BMC Setting -> Date and Time -> Enable NTP 3. Dynamic DNS -> Switch Dynamic Update to "Enable" -> Switch TSIG Authentication to "Enable" -> Upload TSIG .key and .private File 4. Maintenance -> Maintenance Event Log 5. Dynamic DNS -> Switch TSIG Authentication to "Disable" -> Press "Save" 6. Maintenance -> Maintenance Event Log 3. Category: Fix Description: [162851] ECO -- 20122 -- 01.03.03(2023/09/08) -- IPv4 DNS setting comparison wasn't the same after executing "ChangeBmcCfg" (TC3073) Impact motherboard: X12SPO, X12DPU Affected functions: Validation: 1.Run SUMECO TC3073 4. Category: Fix Description: [161753] ECO -- 20122 -- 01.03.02(2023/08/16) -- WEB -- Alert dialog doesn't disappear when navigating to License page via license tip Impact motherboard: X12SPO, X12DPU Affected functions: License Activation Validation: 1.Clear all license 2.Enter to Notification page and edit one alert 3.Move click cursor to Redfish or SNMPv3 radio button 4.Tap on "Start it now" text 5.After the page redirection, the license tip will disappear. 5. Category: Fix Description: [162845] ECO -- 20122 -- 01.03.03(2023/09/08) -- WEB -- Syslog license dialog message doesn't match with spec content Impact motherboard: X12SPO, X12DPU Affected functions: Validation: 1.Clear all license 2.Enter to "Syslog" page 3.Check license dialog text 6. Category: Fix Description: [162781] STD -- 16416 -- 01.03.02(09/12/2023) -- Could not mount ISO with 'http' protocol Impact motherboard: X12SPO, X12DPU Affected functions: Validation: 1. Log into Web GUI and change page to Configuration -> Virtual Media 2. Choice 'Dvice 1' to press down 'pen' icon 3. Type 'http://10.184.31.1' to 'File Server' 4. Type '/iso/efishell.iso' to 'Path to Image' 5. Empty the 'Username' and 'Password' 6. Press down button 'Save' 7. Click 'click to connect' icon 8. Confirm whether the ISO mount successfully 7. Category: Fix Description: [160424] STD -- 16914 -- 01.03.03 -- Switch Lan Interface to Dedicated might lose OOB connection between host OS to BMC [161863] ECO -- 16914 -- 01.01.44 -- SUM Test case fails: 0030 - Ping BMC IP from SUT with different LAN interface. Impact motherboard: X12SPI Affected functions: Validation: 1. Enter OS and run lan_switch_test.sh. 2. Check the ping instruction and network connection. 8. Category: Fix Description: [162369] [Redfish] Redfish automation has 8 fails. Impact motherboard: X12DPU, X12DHM Affected functions: Validation: 1. Install U.2 NVMe drives on BPN 2. Check if Redfish automation can pass for "Test Multipartpush Update BIOS OnReset" and "Check NVMeSSD Version" of Redfish automation 9. Category: Fix Description: [162844] STD -- 21603 -- 01.01.05 (2023/09/08) -- WEB -- MEL is incorrect after do ikvm reset Impact motherboard: X12SPO, X12DPU Affected functions: Validation: 1. Login web with ADMIN. 2. Remote Control -> Current Interface -> Press "Lanuch Console" 3. IKVM Rest -> Press "Rest" 4. Maintenance -> Maintenance Event Log 10. Category: New Feature Description: Support AD DNS Lookup Impact motherboard: X12SPO, X12DPU Validation: 1. Please refer to the spec: https://portal.supermicro.com/Docs/Products%20Management/Software/13_FW%20Projects/BMC/X12/BMC%20Feature%20Specs/AD_DNS_Lookup/Proposal%20for%20Active%20Directory%20enhancement%20V08.pptx 11. Category: New Feature Description: Support RMCP+ Cipher Suite 15/16/17 Impact motherboard: X12SPO, X12DPU Validation: 1. Issue the following raw command to factory default BMC. ipmitool -H {IP} -U {USER} -P {PASS} raw 0x30 0x41 2. Issue the following command to use RMCP+ CS17. ipmitool -H {IP} -U {USER} -P {PASS} -I lanplus -C 17 mc info 12. Category: Fix Description: [162483] ECO -- 16914 -- 01.03.05 -- After redfish request on NTP and refresh Task List becomes empty Impact motherboard: X12DDW, X12SPO Affected functions: Validation: 1. Go to Maintenance - Task List page. 2. Check running tasks are shown correctly. 13. Category: Fix Description: [161243] ECO -- 16914 -- 01.03.04 -- Active Directory fail to delete server address Impact motherboard: X12DDW, X12SPO Affected functions: Validation: 1. Go to Configuration - Account Services - Directory Service page. 2. Set Server Address should be able to delete without layout change. 14. Category: Fix Description: [160928] STD -- SW-- 01.00.22--Source of MEL "Smash logout was successful" shouldn't show as N/A Impact motherboard: X12SPO, X12DPU Affected functions: Validation: 1. Login by SMASH 2. Check MEL 15. Category: Fix Description: [162260] ECO -- 21603 -- 01.01.03 -- SNMP(User) Auth/Private Key naming not match with MEL Impact motherboard: X12SPO, X12DPU Affected functions: Validation: 1. Login BMC WEB 2. Add New User in Account Services-> Users-> Add, setting as below screenshot 3. Check MEL 16. Category: Fix Description: [162263] ECO -- 21603 -- 01.01.03 -- SNMPv3(Alert) Authentication/Encryption Protocol naming not match with MEL Impact motherboard: X12SPO, X12DPU Affected functions: Validation: 1. Login BMC WEB 2. Enable SNMP by Configuration-> Notifications-> SNMP 3. Enable SNMPv3 by Configuration-> Notifications-> SNMP-> SNMPv3 4. Set Protocol to HMAC_SHA96 / CFB128_AES128, then 'Save' 5. Set Protocol to HMAC_SHA96 / CBC_DES, then 'Save' 6. Set Protocol to Account / Account, then 'Save' 7. Check MEL 17. Category: Fix Description: ECO -- 22715 -- 01.01.14(08/11/2023) -- MEL -- [MEL-0094] Event log subscription not match with spec define Impact motherboard: X12SPO, X12DPU Affected functions: Validation : 1. should not need "IP address" String Protection maps: X12DAI-N6-20220614-152047.bin X12DDW-20200618-150509.bin X12DHM-20220912-161301.bin X12DPFR-AN6-20201110-171036.bin X12DPG-AR6-20220616-170358.bin X12DPG-QBT6.bin X12DPG-QT6.bin X12DPG-U6.bin X12DPi-20230222-165258.bin X12DPL.bin X12DPU-20220912-161301.bin X12DSC-A6.bin X12SPED.bin X12SPI-TF-20220615-135812.bin X12SPL-F(-LN4F)-20220615-105913.bin X12SPM.bin X12SPO.bin X12SPW-F(-TF)-20220629-142628.bin X12SPZ.bin ============================================================================================================================== Filename: BMC_X12AST2600-ROT-5201MS_20230904_01.03.05_STDsp.bin version:01.03.05 BuildDate: 2023-09-04 U-Boot baseline : 2019.04 Java SOL Viewer version : v0.5.16 Java iKVM Viewer version : v1.69.53 Redfish API : X12_Redfish_1_11_API_full_list_20230824 TEE Package dateCode: 20210911 pooh.ko: 3.0.5 tee.bin: 0000.00.29 antiRBID: 0x0001 RNDIS|CDC-ECM: RNDIS only Supported MBs: X12DPI-6, X12DPU-6, X12DDW-A6, X12DPG-QT6, X12DHM, X12DPFR-AN6, X12DAI-N6, X12DPG-AR6, X12DPG-U6, X12DPL-I6, X12DSC-A6 X12SPW-TF/-F, X12SPi-TF, X12SPO-F/-NTF, X12SPZ-SPLN6F, X12SPM-TF/-LN4F/-LN6TF, X12SPL-F/-LN4F, X12SPED-F, X12DPG-QBT6 1. Category: Fix Description: [161637] [IPMI ECO 1.03.04]Redfish automation failure. Impact motherboard: X12SPI, X12DPI Affected functions: Validation: 1. Run SATC 2. Category: Fix Description: Set IPV6 and delete IPv6 through SMCIPMITOOL failed follows issue [154331] Impact motherboard: X12DPI Affected functions: Validation : 1. "ipmi lan ipv6 dns $IPV6" via SMCIPMITOOL shell 2. "ipmi lan ipv6 dns" via SMCIPMITOOL shell 3. "ipmi lan ipv6 dns clear" via SMCIPMITOOL shell 3. Category: Fix Description: [161104] ECO -- 16914 -- 01.03.04 (2023/08/17) -- WEB -- No general MEL after add IPv6 Gateway IP. Impact motherboard: X12DPU Affected functions: Validation: 1. Go to Configuration - Network - Network page. 2. Set IPv6 Gateway IP. 3. Go to Maintenance - Maintenance Event Log page. 4. Check [MEL-0256] 4. Category: Fixed Description: [160986]ECO -- 16914 -- 01.03.04(2023/07/14) -- WEB -- Unable to delete LDAP and AD server address Copy Project Issue Link Impact motherboard: X12DPI Affected functions: Validation: 1.Exexute "ipmi raw 30 41" 2.Enter to Directory Service page 3.Enable LDAP and add a server address then submit it 4.Delete server address and submit it 5.Enable Active Directory and add a server address then submit it 6.Delete server address and submit it 5. Category: Fix Description: [160735] ECO -- 16914 --01.03.03_2023/07/14 -- SUM2.11.0-p3_20230714 -- Failed to Set LAN AutoConfiguration DHCPv6Mode Configuration for test "Change LAN via BMC configuration". [160239] ECO -- 16914 -- 01.03.03(07/14/2023) -- SUM -- Failed to Set LAN AutoConfiguration DHCPv6Mode via ChangeBmcCfg (TC3073, TC3088) Impact motherboard: X12SPM, X12SPO Affected functions: Validation: 1. Run SUMECO 6. Category: Fix Description: [160873] STD -- HW-- 01.00.22-- Trash can on Task page is not grayout when system is on lockdown mode Impact motherboard: X12DPI Affected functions: Validation: 1. Go to Maintenance - Firmware Management - Update page. 2. Upload BIOS and select update on next boot. 3. Go to Configuration - BMC Settings - System Lockdown page. 4. Turn on system lockdown. 5. Go to Maintenance - Task List page. 6. Task delete icon should not be shown while system is in lockdown mode. 7. Category: Fix Description: [160187] [16728 -- ECO -- 01.01.16] Deleting a non-existent user in SMCIPMITool will display a completion message and create an entry in the Maintenance Event Log stating "Local user ID 9 was deleted successfully". Impact motherboard: X12DPI Affected functions: Validation: 1. Use SMCIPMITool to delete a non-existent user 8. Category: Fix Description: [153524] Redfish -- Get BootOptions Failed on Redfish with Status Code 404 Impact motherboard: X12DPI Affected functions: Validation: 1. Check Bios boot options features at /redfish/v1/Systems/1 are normal. 2. Pass the Redfish.Systems.BootOptions automation 9. Category: Fix Description: [160738] [IPMI ECO 01.03.03]Update BIOS will show message about "backup and golden image update" via WebUI. Impact motherboard: X12SPL Affected functions: Validation: 1. Go to Maintenance - Firmware Management - Update page. 2. BIOS update should not display update backup and golden image because the rollback is is not higher than the current one. Protection maps: X12DAI-N6-20220614-152047.bin X12DDW-20200618-150509.bin X12DHM-20220912-161301.bin X12DPFR-AN6-20201110-171036.bin X12DPG-AR6-20220616-170358.bin X12DPG-QBT6.bin X12DPG-QT6.bin X12DPG-U6.bin X12DPi-20230222-165258.bin X12DPL.bin X12DPU-20220912-161301.bin X12DSC-A6.bin X12SPED.bin X12SPI-TF-20220615-135812.bin X12SPL-F(-LN4F)-20220615-105913.bin X12SPM.bin X12SPO.bin X12SPW-F(-TF)-20220629-142628.bin X12SPZ.bin ============================================================================================================================== Filename: BMC_X12AST2600-ROT-5201MS_20230817_01.03.04_STDsp.bin version:01.03.04 BuildDate: 2023-08-17 U-Boot baseline : 2019.04 Java SOL Viewer version : v0.5.16 Java iKVM Viewer version : v1.69.52 Redfish API : Redfish_1_11_API_full_list_20230320 TEE Package dateCode: 20210911 pooh.ko: 3.0.5 tee.bin: 0000.00.29 antiRBID: 0x0001 Supported MBs: X12DPI-6, X12DPU-6, X12DDW-A6, X12DPG-QT6, X12DHM, X12DPFR-AN6, X12DAI-N6, X12DPG-AR6, X12DPG-U6, X12DPL-I6, X12DSC-A6 X12SPW-TF/-F, X12SPi-TF, X12SPO-F/-NTF, X12SPZ-SPLN6F, X12SPM-TF/-LN4F/-LN6TF, X12SPL-F/-LN4F, X12SPED-F, X12DPG-QBT6 1. Category: Fix Description: [160738] [IPMI ECO 01.03.03]Update BIOS will show message about "backup and golden image update" via WebUI. Impact motherboard: X12SPL Affected functions: Validation: 1. Go to Maintenance - Firmware Management - Update page. 2. BIOS update should not display update backup and golden image because the rollback is is not higher than the current one. 2. Category: Fix Description: [160391][SUM_v2.12.0(20230802)] Execute TC3034/3053(In-Band-MountIsoImage), the result shows "Mount ISO failed, FF(Undefined completion code=FFh)" while the ISO has been successfully mounted Impact motherboard: X12DDW-A6 Affected functions: Validation: 1. Run TC3034/3053(In-Band-MountIsoImage) 3. Category: Fix Description: BIOS Setting Extreme Performance will cause system unable to boot to the BIOS Impact motherboard: X12DDW Affected functions: Validation: 1. Follow the description is in the issueID, or consult Tim Guo. 4. Category: Fix Description: [160472] ECO -- 16914 -- 01.03.03(07/14/2023) -- GUI -- DNS server IP rasio buttons aren't disabled on the user permission. Impact motherboard: X12DPL Affected functions: Validation: 1. Go to Configuration - Network - Network page. 2. User privilege should not be able to click radio button of DNS server. 5. Category: Fix Description: [160511] Could not mount ISO via SMCIPMITool when Virtual Media does not mount any ISO or floppy Impact motherboard: H13SVW-NT Affected functions: Validation: 1. Mount VM with different configurations via SMCIPMITool successfully 6. Category: Fix Description: [160532] STD -- HW-- 01.01.01-- Need to define MEL-ID for "LLDP was configured to enabled/disabled successfull Impact motherboard: All MBs Affected functions: Validation: 1. Login BMC WEB, Go to Configuration - Network - LLDP page 2. Enable LLDP and Save 3. Disable LLDP and Save 4. Check MEL 7. Category: Fix Description: [159977] ECO -- 16914 -- 01.03.03(07/14/2023) -- SMCIPMITool -- Can't enable/disable ipv6 autoconfig with smcipmitool command [160239] ECO -- 16914 -- 01.03.03(07/14/2023) -- SUM -- Failed to Set LAN AutoConfiguration DHCPv6Mode via ChangeBmcCfg (TC3073, TC3088) Impact motherboard: X12SPW Affected functions: Validation: 1. Login BMC via smcipmitool 2. Executed cmd: ipmi lan lpv6 autoconfig 0 3. Run SUMECO 8. Category: Fix Description: [158900] NvME info should be the same after UpdateBMC Fail [160218] [AS-1115SV-WTNRT_EVT_H1] The NVMe info is incorrect Impact motherboard: X12DPG-QT6 MB for [158900] H13SVW-NT MB for [160218] Affected functions: Validation: 1. Install Samsung PM1752a MZWLL800HEHP-00003 for [158900] Install SAMSUNG PM983 MZQLB960HAJR-00007 for [160218] 2. Check if the Max Link Speed of this drive is 8.0 GT/s in WebUI 9. Category: Fix Description: [159810] ECO -- 16914 -- 01.03.03(07/14/2023) -- SNMP OID 'UID' always get 0 whatever UID switch to ON or OFF Impact motherboard: X12SPI-TF Affected functions: Validation: 1. Add User to access SNMP function 2. Enable SNMPv2 and v3 2. Login Web GUI to Dashboar -> Overview 3. Switch 'UID Control' to 'ON' 4. Type SNMPv2 command to get UID status 'snmpget -v2c -c public 1.3.6.1.4.1.21317.1.10.0' 5. Type SNMPv3 command to get UID status 'snmpget -v3 -u -a MD5 -A "*****" -x DES -X "*****" -l authPriv 1.3.6.1.4.1.21317.1.10.0' 6. Check return code 10. Category: Fixed Description: R: [158637][157597][156833][152058] Fix SSM Diagnose System fail due to PATCH Redifsh bios API return 500 internal error Impact motherboard: H13SVW, X13DDW, X12STD, H13SSW Affected functions: Validation: 1. Run SSM Diagnose System without Failed to restore the BIOS configurations error 11. Category: Fix Description: [158276] Redfish Hostname special characters support Impact motherboard: X12 Affected functions: Validation: 1.curl -s -k -u ADMIN:ADMIN https://172.31.49.194/redfish/v1/Managers/1/EthernetInterfaces/1 -X PATCH -H 'Content-Type': 'application/json' -d '{"HostName": "local+2"}' | jq 2.only accpet [A-Za-z0-9] and hyphen[-] ============================================================================================================================== Filename: BMC_X12AST2600-ROT-5201MS_20230714_01.03.03_STDsp.bin version:01.03.03 BuildDate: 2023-07-14 U-Boot baseline : 2019.04 Java SOL Viewer version : v0.5.16 Java iKVM Viewer version : v1.69.52 Redfish API : Redfish_1_11_API_full_list_20230320 TEE Package dateCode: 20210911 pooh.ko: 3.0.5 tee.bin: 0000.00.29 antiRBID: 0x0001 Supported MBs: X12DPI-6, X12DPU-6, X12DDW-A6, X12DPG-QT6, X12DHM, X12DPFR-AN6, X12DAI-N6, X12DPG-AR6, X12DPG-U6, X12DPL-I6, X12DSC-A6 X12SPW-TF/-F, X12SPi-TF, X12SPO-F/-NTF, X12SPZ-SPLN6F, X12SPM-TF/-LN4F/-LN6TF, X12SPL-F/-LN4F, X12SPED-F, X12DPG-QBT6 1. Category: New Feature Description: 2022/Q1_Q2 Phase 1 (Ticket #299-00-220311-001) (http://super-form.supermicro.com/Home/WorkFlow/eForm/Preview?docId=c37217ed-e3d3-4915-a8b9-39c1b7b6098d) Impact motherboard: All X12 MBs Affected functions: Validation: 1. DMTF tool validation Run SATC automation test. - Protocol Validator - Service Validator - Reference Checker 2. Default setting HTML5 Console as default (Add default setting in Web UI spec) Dual mode for network setting as default (Add default setting in Web UI spec) 3. Disable IPMI Lan Port Interface By default, it is still eabled Customer can disable via Web UI, Redfish 4. IPMI OEM command 0x30 0x68 0x28 (RoT provisioning) 0x30 0x68 0x27 (Get current BOOTID) 0x30 0x70 0x6C (Get Set NvME SSD values, Get BPN ID) 0x30 0x70 0x0C (IPMI LAN mode) 5. BMC each field ver. 1.32 6. OpenSSL upgrade to 1.1.1 7. BMC vulnerability fixing (VRM overvoliting undervolting) V07 8. Web UI, Warning message while disabling SMC RAKP 9. OOB feature SSD and HDD - Indicator for drive location, when drive is malfucntion - BMC recoginze on which drive is malfucntion, 3916, StoriCLI (minimum command list) - BMC Web UI, Blinking Red icon to Indicate for which drive is malfunction 10. Redfish 2020.3 upgrade 11. VM, 3 ISO file mounting 12. Link Layer Discovery Protocol (LLDP) support 2. Category: Enhancement Description: 2021/Q1_Q2 (Ticket #299-00-210204-001) (http://super-form.supermicro.com/Home/WorkFlow/eForm/Preview?docId=527f1ee9-6f6e-4546-a475-e02f1b737b4b) Impact motherboard: All X12 MBs Affected functions: Validation: IPv6 Enhancement https://portal.supermicro.com/Docs/Products%20Management/Software/13_FW%20Projects/BMC/X12/BMC%20Feature%20Specs/Q1%202021%20Features%20list/Proposal%20for%20BIOS-BMC%20IPv6%20inconsistency_V11.pptx 3. Category: Fix Description: [157552] Downgrade from BIOS1.3 to BIOS1.1, BIOS shown correct, but IPMI web still show BIOS1.3 Impact motherboard: ROT1,ROT1+,ROT2-HW2 platforms Affected functions: bios fwUP Validation: 1. Idenifty a new bios fw which support CDC-ECM feature. For X13, it should be ver 1.3 2. Indentify an old bios fw which support RNDIS feature. For X13, it should be ver 1.1 3. webGUI bios fwUP between 1) and 2). Monitor the bios fw version string and dateCode info in webGUI dahsboard. 4. In addition, the updated bios info should be presented in webGUI dashboard right after the cpld bios update operation, in which no need to wait bios boot up to End-Of-Post. 4. Category: Fix Description: [156577] ECO -- 21604 -- 01.00.18 -- [MEL] duplicate [MEL-0137] when setup SMTP Impact motherboard: H13DSG Affected functions: Validation: 1.Login BMC web 2.Go to [SMTP] page 3.Set [UserName] then view the MELs 5. Category: Fix Description: [156798] ECO -- 16914 -- 01.01.43 -- [MEL] MEL log not quite match when setup Alert SNMPv3 Authentication/ Encryption Protocol Impact motherboard: X12DHM Affected functions: Validation: 1.Login BMC web 2.Go to [Alert] page 3.Set [Enable], [Disable] then view the MELs of [Severity] 6. Category: Fix Description: [145792] ECO -- 16914 -- 01.01.28 -- No related MEL when setup Active Directory (either setup by SMCIPMITOOL) [145773] ECO -- 16914 -- 01.01.28 -- No related MEL when setup LDAP (either setup by SMCIPMITOOL) Impact motherboard: X12DPL Affected functions: Validation: 1.Login BMC web 2.Go to [Directory] page 3.Input [Remote User], [Remote Group], [Role] fields 7. Category: Fix Description: [156116] ECO -- 19328 -- 01.01.11 -- DLAP and Active Directory Add Rule requires both Remote User and Remote Group to be filled when other type B UI only require one Impact motherboard: X12DSC Affected functions: Validation: 1.Login BMC web 2.Go to [Directory] page 3.Input [Remote User], [Remote Group] fields 8. Category: New feature Description: Support IPv6 enhancement spec. (Proposal for BIOS-BMC IPv6 inconsistency_V11.pptx) Impact motherboard: All X12 MBs. Affected functions: Validation: 1. IPv6 features should follow the spec. 9. Category: Fix Description: [157570] [IPMI 01.01.04] Redfish SATC automation test has failed. Impact motherboard: All MBs. Affected functions: Validation: 1. GET request on /redfish/v1/Chassis/StorageBackplane/Drives and check if "Members@odata.count" exists. 2. PUT request on /redfish/v1/Chassis/StorageBackplane/Drives/Disk.Bay.0 should return 405. 3. Align drives privilege with redfish full list 0613. 10. Category: Fix Description: [157718] ECO -- 21603 -- 01.00.19 (2023/05/26) -- GUI -- Table fields should be display complete. Impact motherboard: H13DSG Affected functions: Validation: 1. Go to Configuration - Account Services - Directory Service page. 2. Change language and check the UI layout. 3. Go to Maintenance - Troubleshooting - Console Capture page. 4. Change language and check the UI layout. 11. Category: Fix Description: [157068] STD--SW--01.01.14-- LNR and LCT of MB Hot Swap Temp mismatch Impact motherboard: X12DGO Affected functions: Validation: 1. Eamine the "MB Hot Swap Temp" sensor LNR|NC values by the following 3 methods: + webGUI -> Sensor Reading page + SMCIPMITool ipmi sensor + ipmitool snesor list (cherry picked from commit 9805079626878d66934d4517903005dbad63dfa3) 12. Category: Fix Description: [153032] New Feature --21992 -- 09.01.01 -- [Kendo] Keyword in search bar will be clear after disable thresholds [153091] New Feature--18367--09.02.15(02/14/2023)-- [Kendo] Keyword in search bar will be clear after Turn "OFF" thresholds. Impact motherboard: X13SET-GC Affected functions: Validation: 1.Login BMC web 2.Go to [Sensor] page 3.Key-in keyword to filter data, then show/hide threshold 13. Category: Fix Description: [153077] New Feature --21992 -- 09.01.01 -- [Kendo] Smart Power information is not complete when zooming from 100% Impact motherboard: X13SET-GC Affected functions: Validation: 1.Login BMC web 2.Go to [Smart Power] page 3.Zoom-in/Out 14. Category: Fix Description: [153111] New Feature--18367--09.02.15(02/14/2023)--[Kendo] Add new user tips is exceed the frame when zooming to 110% (Browser: Edge) Impact motherboard: X12DPI-N6 Affected functions: Validation: 1. Go to Configuration - Account Services - Users page. 2. Check help tips when adding a new user on Edge at 110% zoom. 15. Category: Fix Description: [153227] Beta-- upgrade Kendo -- 21992 -- 09.02.15(02/14/2023) -- Can't generate evidence after recovery BMC/BIOS Impact motherboard: X13SEW-F Affected functions: Validation: 1. Go to Maintenance - Firmware Management - Inventory page. 2. Check BMC/BIOS should be able to generate and download evidence after recovery. 16. Category: Fix Description: [153115] New Feature --21992 -- 09.01.01 -- [Kendo] Upload invalid Device 0 file help tips is overlap when zoom in to 125% with 14" inch and 175% & 200% with 22" inch Impact motherboard: All X12/X13 platforms Affected functions: Task List Validation: 1. Login BMC web GUI ->Go Configuration-> Maintenance -> Firmware Management 2. Select "Device 0" 3. Press Next 4. Upload invalid file 5. Zooming in/out of web page from difference %, check UI display50%, 67%, 75%, 80%, 90%, 100%, 110%, 125% 150%, 175%, 200%(Chrome) 6. Check tips 17. Category: Fix Description: [153153] New Feature --21992 -- 09.01.01 -- [Kendo] Health status of task list is not complete when zoom in from 75% to 200% Impact motherboard: All X12/X13 platforms Affected functions: Task List Validation: 1. Login WEBUI -> Maintenance -> Task List 2. Zooming in/out of web page from difference %, check UI display 50%, 67%, 75%, 80%, 90%, 100%, 110%, 125% 150%, 175%, 200%(Chrome) 3. Check "Health Status" 18. Category: Fix Description: [153067] New Feature--18367--09.02.15(02/14/2023)--[Kendo]DDNS upload invalid key help tips is overlap when zooming to 200%. Impact motherboard: All X12/X13 platforms Affected functions: Dynamic DNS Validation: 1. Login BMC web GUI ->Go Configuration-> BMC Settings -> DDNS 2. Enable DDNS and Enable TSIG Authentication 3. Upload Invalid key with TSIG .key File and TSIG .private File For example: txt file 4. Zooming in/out of web page from difference %, check help tips 100%, 110%, 125%, 150%, 175%, 200% (Edge) 100%, 110%, 120%, 130%, 140%, 150%, 160%, 170%, 180%, 190%, 200% (Firefox) 5. Check error message 19. Category: Fix Description: [153097] New Feature --21992 -- 09.01.01 -- [Kendo] NTP server error message will exceed the fram and overlap with side bar when zoom in from 100% Impact motherboard: All X12/X13 platforms Affected functions: Date and Time Validation: 1. Login BMC web GUI-> Configuration -> BMC Settings -> Date and Time 2. Enable NTP 3. Enter invalid NTP server 4. Zooming in/out of web page from difference %, check UI display 50%, 67%, 75%, 80%, 90%, 100%, 110%, 125% 150%, 175%, 200%(Chrome) 5. Check error message 20. Category: Fix Description: [153113] New Feature --21992 -- 09.01.01 -- [Kendo] Upload invalid IPMI Configuration file help tips is overlap when zoom in to 200% Impact motherboard: All X13 platforms Affected functions: IPMI Configuration Validation: 1. Login BMC web GUI ->Go Configuration-> BMC Settings -> IPMI Configuration 2. Upload invalid file to "Reload IPMI Configuration" 3. Zooming in/out of web page from difference %, check UI display 50%, 67%, 75%, 80%, 90%, 100%, 110%, 125% 150%, 175%, 200%(Chrome) 4. Check tips 21. Category: Fix Description: [153069] New Feature --21992 -- 09.01.01 -- [Kendo] Power consumption is not complete when zooming from 110% Impact motherboard: All X13 platforms Affected functions: Dashboard Validation: 1. Login BMC web GUI -> Dashboard 2. Check Power Consumption 3. Zooming in/out of web page from difference %, check UI display 50%, 67%, 75%, 80%, 90%, 100%, 110%, 125% 150%, 175%, 200%(Chrome) 22. Category: Fix Description: [153012] New Feature--18367--09.02.15(02/14/2023)--[Kendo]Sensor thresholds columns should not hide when export to Excel file. [153005] New Feature--21992--09.02.15(02/14/2023)--[Kendo]Sensor thresholds is not complete/overlap/disappear when zooming from 100%. Impact motherboard: X12DPI-N6 Affected functions: Validation: 1.Go to [Sensor Reading] 2.Turn on Thresholds and check it with Zoom-in/Out page 3.Download excel file and check columns width 23. Category: Fix Description: [156797] ECO -- 16914 -- 01.01.43 -- [MEL] No related MEL when setup User with Account Type SNMP (Auth Protocol / Private Protocol) Impact motherboard: X12DHM Affected functions: Validation: 1.Login BMC web 2.Go to [User] page 3.Input SNMP related setting 24. Category: Fix Description: [157592] [IPMI ECO 1.01.43]Sensor naming not match with sensor specification Impact motherboard: X12DPG-QT Affected functions: Validation: 1. webGUI -> Sensor Readings. Observe the onboard M2 temeperature sensor naming. (cherry picked from commit 35c540e42aa60beb6b08b56f33242ad29dc75c03) 25. Category: Fix Description: [157592] [IPMI ECO 1.01.43]Sensor naming not match with sensor specification Impact motherboard: X12SPI Affected functions: Validation: 1. webGUI -> Sensor Readings. Observe the onboard M2 temeperature sensor naming. 26. Category: Fix Description: [150747] ECO --16914 -- 01.01.31 (12/09/2022) -- WEB -- Invalid Sensor name. Impact motherboard: X12SCZ Affected functions: Validation : 1. Login with ADMIN 2. System → Component Info → Sensor 3. Should match with SPEC. (cherry picked from commit e2baacfb4a63e214054c720d406a55e4da2a1b75) 27. Category: Enhancement Description: Remove static onboard LAN sensor to detect AOM card dynamically. Impact motherboard: H12DSG-Q Affected functions: Validation: 1. Update the BIOS to a version higher than 2.5 2. Use the "sdr list" command of ipmitool to check whether the original onboard LAN static sensor exists. 3. In the IPMI WEB, you can see the information and temperature of the AOM card on the "Network AOC" page. 28. Category: Fix Description: [157472] ECO -- 20899 -- 01.00.54 -- [GUI] SNMPv3 description in Help page is not aligned with web GUI Impact motherboard: X13DAi Affected functions: Validation: 1.Login BMC web 2.Open help page 3.Check wordings 29. Category: Fix Description: [157066] STD--SW--01.01.14-- Webgui crashed after uploading product key with invalid file Impact motherboard: X12DGO-6 Affected functions: Validation: 1. Go to Maintenance - License Activation page. 2. Select invalid file. 3. Show error message and disallow to click upload button. 30. Category: Fix Description: [156203] [IPMI ECO 01.00.18]Enable and Disable LDAP/Active Directory haven't record in MEL. [156493] ECO -- 21603 -- 01.00.18 -- No related MEL when enable LDAP and Active Directory (based on MEL SPEC v1.03) [152260] ECO --21603 -- 01.00.12 (01/17/2023) -- WEB -- MEL Log should be record when enable/disable LDAP/Active Directory. [152234] ECO -- 21386 -- 01.01.08 -- [MEL] No related MEL when setup Active Directory [151581] ECO -- 18379 -- 01.01.07 -- [MEL] No related MEL when setup Active Directory (either setup by SMCIPMITOOL) [151580] ECO -- 18379 -- 01.01.07 -- [MEL] No related MEL when setup LDAP (either setup by SMCIPMITOOL) [147072] ECO -- 16099 -- 00.23.70 -- No related MEL when setup Active Directory (either setup by SMCIPMITOOL) [146945] ECO -- 16416 -- 01.01.26 -- No related MEL when setup Active Directory (either setup by SMCIPMITOOL) [146888] ECO -- 16416 -- 01.01.26 -- No related MEL when setup LDAP (either setup by SMCIPMITOOL) [146736] ECO -- 16099 -- 00.23.68 -- No related MEL when setup LDAP (either setup by SMCIPMITOOL) [145792] ECO -- 16914 -- 01.01.28 -- No related MEL when setup Active Directory (either setup by SMCIPMITOOL) [145773] ECO -- 16914 -- 01.01.28 -- No related MEL when setup LDAP (either setup by SMCIPMITOOL) Impact motherboard: H13DSG, H13SSW, H13DSH, X13SET, H12DSG, X12SPG, X12SCZ, X12QCH, X12DPL Affected functions: Validation: 1.Login BMC web 2.Go to [Directory Service] page 3.Input related setting 4.Check MELs 31. Category: Fix Description: [156798] ECO -- 16914 -- 01.01.43 -- [MEL] MEL log not quite match when setup Alert SNMPv3 Authentication/ Encryption Protocol [156797] ECO -- 16914 -- 01.01.43 -- [MEL] No related MEL when setup User with Account Type SNMP (Auth Protocol / Private Protocol) [157272] ECO—16914—01.01.44 (05/12/2023)—[MEL] MEL log not quite match when setup Alert Redfish Protocol. [156499] ECO -- 21603 -- 01.00.18 -- [MEL] generated MEL not quite match when setup Alert SNMPv3 (based on MEL SPEC v1.03) Impact motherboard: X12DHM-6 H13DSG-O-CPU Affected functions: Validation: 1.Login BMC web 2.Go to [Alert] page 3.Input related setting 4.Check MELs 32. Category: Fix Description: [156577] ECO -- 21604 -- 01.00.18 -- [MEL] duplicate [MEL-0137] when setup SMTP Impact motherboard: H13DSG-O-CPU Affected functions: Validation: 1.Login BMC web 2.Go to [SMTP] page 3.Modify setting 4.Check MELs 33. Category: Fix Description: [156498] ECO -- 21603 -- 01.00.18 -- [MEL] should non-set IPv4 DNS Server IP related MEL be shown when setup IPv6 DNS Server IP or not Impact motherboard: H13DSG-O-CPU Affected functions: Validation: 1.Login BMC web 2.Go to [Network] page 3.Add then remove IPv6 DNS 4.Check MELs 34. Category: Fix Description: [151083] STD-01.00.05-SmartPower difference between SW/HW1 Impact motherboard: X13 Affected functions: Validation: 1.Login BMC web 2.Go to [Smart Power] page 3.Check the title wording 35. Category: New Description: [156694] RTX6000 ada GPU threshold is not correct Support RTX6000 ADA Impact motherboard: X12DAI Affected functions: Validation: 1. ipmitool sensor list. Observe the GPU temperature UC and UNR values. 36. Category: Fix Description: [156362] ECO -- 16914 -- 01.01.43 -- DIMM Sensor name Impact motherboard: X12SPED Affected functions: Validation: 1. webGUI -> Sensor Readings, check if sensor names meet spec. 37. Category: Fix Description: [156983] STD--SW--11.00.18-- Duplicate "Network AOC" on dashboard when system is in lockdown mode Impact motherboard: H13DSH Affected functions: Validation: 1. Go to Configuration - BMC Settings - System Lockdown page. 2. Turn on system lockdown and redirect to dashboard page. 3. Check Network AOC link should be only one. 38. Category: Fix Description: [156888] ECO -- 16914 -- 01.01.43(20230426) -- Sensor naming doesn't match the spec. Impact motherboard: X12SPO Affected functions: Validation: 1. webGUI -> Sensor Readings. Observe the sensor naming of DIMMA~D, DIMME~H, M2_SSD1, and M2_SSD2. (cherry picked from commit 4de29d90ca1434b8588d4ea1b7abdb4d6729a79c) 39. Category: New Description: [156694] RTX6000 ada GPU threshold is not correct Support RTX6000 ADA Impact motherboard: X12DAI Affected functions: Validation: 1. ipmitool sensor list. Observe the GPU temperature UC and UNR values. 40. Category: Fix Description: [159007] SW--STD--01.03.02--IPMIECO test failed [158676] STD--SW--01.03.02--IPMIECO Automation Test failed Impact motherboard: X12DPFR-AN6 Affected functions: Validation: 1.Run [IPMIECO], by ATT ver : 2023/07/10 and SUM ver : /att/sum/2.12.0_20230628 41. Category: Fix Description: [159197] STD -- SW-- 01.03.02-- User is able to click switching Smart Power button under System lockdown mode Impact motherboard: X12DPFR-AN6 Affected functions: Validation: 1.Login BMC web 2.Turn on System Lockdown 3.Check switch of smart power 42. Category: Fix Description: [159141] STD -- SW-- 01.03.02-- Hint message misplacement Impact motherboard: X12DPFR-AN6 Affected functions: Validation: 1.Login BMC web 2.Go to [Directory Service] page 3.Check layout 43. Category: Fix Description: [159014] STD -- SW-- 01.03.02-- Typo on Network page Impact motherboard: X12DPFR-AN6 Affected functions: Validation: 1.Login BMC web 2.Go to [Network] page 3.Check field's naming is [UDID] 44. Category: Fix Description: [156576] ECO -- 21603 -- 01.00.18 -- [MEL] generated MEL not quite match when add SNMPv2 (based on MEL SPEC v1.03) Impact motherboard: H13DSG-O-CPU Affected functions: Validation: 1.Login BMC web 2.Go to [SNMP] page 3.Input several communities and check MELs 45. Category: Fix Description: OEM-Telus -- 19018 -- 11.03.32 (06/26/2023) -- WEB -- BMC version is incorrect in troubleshooting Log. Impact motherboard: ALL Affected functions: Validation : 1. Login web with ADMIN. 2. Maintenance → Troubleshooting → System Crash Dump → Troubleshooting Log → Click "Generate" → Waiting few mins → Click "Download" 3. Open troubleshooting log 4. Compare version with log 46. Category: Fix Description: [158491] STD--HW--01.00.55 -- Incorrect MEL after deleting IP control rule Impact motherboard: X13DGU Affected functions: Validation: 1. Login webgui 2. Go to Network 3. Go to IP Access Control page 4. Add a new IP Access Control 5. Delete it 6. Check MEL 47. Category: Fix Description: [158352] ECO—21386—01.00.16 (06/05/2023)—[MEL-0036] format not quite match with Spec definition. Impact motherboard: X13SET-GC Affected functions: Validation: 1.Login BMC web 2.Go to [Directory Service] 3.Input [c=season,cn=Users,dc=satc,dc=com] into [Remote Group], then check the MELs 48. Category: Fix Description: [158645] [BIOS ECO 1.0]SUM ATT Test fail Impact motherboard: H13SAE-MF Affected functions: Validation: 1.RUN SMCTC TC4011-4013 49. Category: Fix Description: [158612] STD -- 20899 -- 01.01.01(05/19/2023) -- GUI -- Still prompt error tips when type the path first and then the file server Impact motherboard: MBD-X13SEW-F-P Affected functions: Virtual Media Validation: 1.Login BMC Web and click Configuration > Virtual Media 2.Edit device1 3.Type the Path first (e.g /Public/ISO/Redhat/RHEL9.1.iso) 4.it will not prompt the error tips after the [Path to Image] field 5.it only appear the required message after the [Share Host]field 50. Category: Fix Description: [157357] [16728 -- ECO -- 01.01.44] Changing Mouse Mode in iKVM generates increasing amounts of Maintenance Event Log entries Impact motherboard: MBD-X12DSC-A6 Affected functions: iKVM Validation: 1. Open iKVM 2. Go to Preferences - Input and change the mouse mode 3. Make sure that each click on mouse mode generates only one MEL log entry. 51. Category: Fix Description: [157516] ECO -- 21603 -- 01.00.19 (2023/05/26) -- GUI -- HDD info lines is not aligned at Physical View Impact motherboard: All X12/X13/H12/H13 MBs. Affected functions: Validation: 1. System → Storage Monitoring → Physical View → Drown down HDD info. 2. Check if disk info lines is not aligned at Physical View. 52. Category: Fix Description: [158276] Redfish Hostname special characters support Impact motherboard: X12 Affected functions: Validation: 1.curl -s -k -u ADMIN:ADMIN https://172.31.49.194/redfish/v1/Managers/1/EthernetInterfaces/1 -X PATCH -H 'Content-Type': 'application/json' -d '{"HostName": "local+2"}' | jq 2.only accpet [A-Za-z0-9] and hyphen[-] 53. Category: Fix Description: [157552] Downgrade from BIOS1.5 to BIOS1.1, BIOS shown correct, but IPMI web still show BIOS1.5 Impact motherboard: ROT1,ROT1+,ROT2-HW2 platforms Affected functions: bios fwUP Validation: 1. Idenifty a new bios fw which support CDC-ECM feature. For X12, it should be ver 1.5 2. Indentify an old bios fw which support RNDIS feature. For X12, it should be ver 1.1 3. webGUI bios fwUP between 1) and 2). Monitor the bios fw version string and dateCode info in webGUI dahsboard. Please try both immedateUpdate mode and onNext mode. They are considered as different test cases in this issueID. 4. In addition, the updated bios info should be presented in webGUI dashboard right after the cpld bios update operation, in which no need to wait bios boot up to End-Of-Post. (cherry picked from commit eda97c916d3219f816c18445b2a912ca9f0f7f14) ============================================================================================================================== Filename: BMC_X12AST2600-ROT-5201MS_20230621_01.03.02_STDsp.bin version:01.03.02 BuildDate: 2023-06-21 U-Boot baseline : 2019.04 Java SOL Viewer version : v0.5.16 Java iKVM Viewer version : v1.69.52 Redfish API : Redfish_1_11_API_full_list_20230320 TEE Package dateCode: 20210911 pooh.ko: 3.0.5 tee.bin: 0000.00.29 antiRBID: 0x0001 Supported MBs: X12DPI-6, X12DPU-6, X12DDW-A6, X12DPG-QT6, X12DHM, X12DPFR-AN6, X12DAI-N6, X12DPG-AR6, X12DPG-U6, X12DPL-I6, X12DSC-A6 X12SPW-TF/-F, X12SPi-TF, X12SPO-F/-NTF, X12SPZ-SPLN6F, X12SPM-TF/-LN4F/-LN6TF, X12SPL-F/-LN4F, X12SPED-F, X12DPG-QBT6 1. Category: New Feature Description: 2022/Q1_Q2 Phase 1 (Ticket #299-00-220311-001) (http://super-form.supermicro.com/Home/WorkFlow/eForm/Preview?docId=c37217ed-e3d3-4915-a8b9-39c1b7b6098d) Impact motherboard: All X12 MBs Affected functions: Validation: 1. DMTF tool validation Run SATC automation test. - Protocol Validator - Service Validator - Reference Checker 2. Default setting HTML5 Console as default (Add default setting in Web UI spec) Dual mode for network setting as default (Add default setting in Web UI spec) 3. Disable IPMI Lan Port Interface By default, it is still eabled Customer can disable via Web UI, Redfish 4. IPMI OEM command 0x30 0x68 0x28 (RoT provisioning) 0x30 0x68 0x27 (Get current BOOTID) 0x30 0x70 0x6C (Get Set NvME SSD values, Get BPN ID) 0x30 0x70 0x0C (IPMI LAN mode) 5. BMC each field ver. 1.32 6. OpenSSL upgrade to 1.1.1 7. BMC vulnerability fixing (VRM overvoliting undervolting) V07 8. Web UI, Warning message while disabling SMC RAKP 9. OOB feature SSD and HDD - Indicator for drive location, when drive is malfucntion - BMC recoginze on which drive is malfucntion, 3916, StoriCLI (minimum command list) - BMC Web UI, Blinking Red icon to Indicate for which drive is malfunction 10. Redfish 2020.3 upgrade 11. VM, 3 ISO file mounting 12. Link Layer Discovery Protocol (LLDP) support 2. Category: Enhancement Description: 2021/Q1_Q2 (Ticket #299-00-210204-001) (http://super-form.supermicro.com/Home/WorkFlow/eForm/Preview?docId=527f1ee9-6f6e-4546-a475-e02f1b737b4b) Impact motherboard: All X12 MBs Affected functions: Validation: IPv6 Enhancement https://portal.supermicro.com/Docs/Products%20Management/Software/13_FW%20Projects/BMC/X12/BMC%20Feature%20Specs/Q1%202021%20Features%20list/Proposal%20for%20BIOS-BMC%20IPv6%20inconsistency_V11.pptx 3. Category: Fix Description: [157552] Downgrade from BIOS1.3 to BIOS1.1, BIOS shown correct, but IPMI web still show BIOS1.3 Impact motherboard: ROT1,ROT1+,ROT2-HW2 platforms Affected functions: bios fwUP Validation: 1. Idenifty a new bios fw which support CDC-ECM feature. For X13, it should be ver 1.3 2. Indentify an old bios fw which support RNDIS feature. For X13, it should be ver 1.1 3. webGUI bios fwUP between 1) and 2). Monitor the bios fw version string and dateCode info in webGUI dahsboard. 4. In addition, the updated bios info should be presented in webGUI dashboard right after the cpld bios update operation, in which no need to wait bios boot up to End-Of-Post. 4. Category: Fix Description: [156577] ECO -- 21604 -- 01.00.18 -- [MEL] duplicate [MEL-0137] when setup SMTP Impact motherboard: H13DSG Affected functions: Validation: 1.Login BMC web 2.Go to [SMTP] page 3.Set [UserName] then view the MELs 5. Category: Fix Description: [156798] ECO -- 16914 -- 01.01.43 -- [MEL] MEL log not quite match when setup Alert SNMPv3 Authentication/ Encryption Protocol Impact motherboard: X12DHM Affected functions: Validation: 1.Login BMC web 2.Go to [Alert] page 3.Set [Enable], [Disable] then view the MELs of [Severity] 6. Category: Fix Description: [145792] ECO -- 16914 -- 01.01.28 -- No related MEL when setup Active Directory (either setup by SMCIPMITOOL) [145773] ECO -- 16914 -- 01.01.28 -- No related MEL when setup LDAP (either setup by SMCIPMITOOL) Impact motherboard: X12DPL Affected functions: Validation: 1.Login BMC web 2.Go to [Directory] page 3.Input [Remote User], [Remote Group], [Role] fields 7. Category: Fix Description: [156116] ECO -- 19328 -- 01.01.11 -- DLAP and Active Directory Add Rule requires both Remote User and Remote Group to be filled when other type B UI only require one Impact motherboard: X12DSC Affected functions: Validation: 1.Login BMC web 2.Go to [Directory] page 3.Input [Remote User], [Remote Group] fields 8. Category: New feature Description: Support IPv6 enhancement spec. (Proposal for BIOS-BMC IPv6 inconsistency_V11.pptx) Impact motherboard: All X12 MBs. Affected functions: Validation: 1. IPv6 features should follow the spec. 9. Category: Fix Description: [157570] [IPMI 01.01.04] Redfish SATC automation test has failed. Impact motherboard: All MBs. Affected functions: Validation: 1. GET request on /redfish/v1/Chassis/StorageBackplane/Drives and check if "Members@odata.count" exists. 2. PUT request on /redfish/v1/Chassis/StorageBackplane/Drives/Disk.Bay.0 should return 405. 3. Align drives privilege with redfish full list 0613. 10. Category: Fix Description: [157718] ECO -- 21603 -- 01.00.19 (2023/05/26) -- GUI -- Table fields should be display complete. Impact motherboard: H13DSG Affected functions: Validation: 1. Go to Configuration - Account Services - Directory Service page. 2. Change language and check the UI layout. 3. Go to Maintenance - Troubleshooting - Console Capture page. 4. Change language and check the UI layout. 11. Category: Fix Description: [157068] STD--SW--01.01.14-- LNR and LCT of MB Hot Swap Temp mismatch Impact motherboard: X12DGO Affected functions: Validation: 1. Eamine the "MB Hot Swap Temp" sensor LNR|NC values by the following 3 methods: + webGUI -> Sensor Reading page + SMCIPMITool ipmi sensor + ipmitool snesor list (cherry picked from commit 9805079626878d66934d4517903005dbad63dfa3) 12. Category: Fix Description: [153032] New Feature --21992 -- 09.01.01 -- [Kendo] Keyword in search bar will be clear after disable thresholds [153091] New Feature--18367--09.02.15(02/14/2023)-- [Kendo] Keyword in search bar will be clear after Turn "OFF" thresholds. Impact motherboard: X13SET-GC Affected functions: Validation: 1.Login BMC web 2.Go to [Sensor] page 3.Key-in keyword to filter data, then show/hide threshold 13. Category: Fix Description: [153077] New Feature --21992 -- 09.01.01 -- [Kendo] Smart Power information is not complete when zooming from 100% Impact motherboard: X13SET-GC Affected functions: Validation: 1.Login BMC web 2.Go to [Smart Power] page 3.Zoom-in/Out 14. Category: Fix Description: [153111] New Feature--18367--09.02.15(02/14/2023)--[Kendo] Add new user tips is exceed the frame when zooming to 110% (Browser: Edge) Impact motherboard: X12DPI-N6 Affected functions: Validation: 1. Go to Configuration - Account Services - Users page. 2. Check help tips when adding a new user on Edge at 110% zoom. 15. Category: Fix Description: [153227] Beta-- upgrade Kendo -- 21992 -- 09.02.15(02/14/2023) -- Can't generate evidence after recovery BMC/BIOS Impact motherboard: X13SEW-F Affected functions: Validation: 1. Go to Maintenance - Firmware Management - Inventory page. 2. Check BMC/BIOS should be able to generate and download evidence after recovery. 16. Category: Fix Description: [153115] New Feature --21992 -- 09.01.01 -- [Kendo] Upload invalid Device 0 file help tips is overlap when zoom in to 125% with 14" inch and 175% & 200% with 22" inch Impact motherboard: All X12/X13 platforms Affected functions: Task List Validation: 1. Login BMC web GUI ->Go Configuration-> Maintenance -> Firmware Management 2. Select "Device 0" 3. Press Next 4. Upload invalid file 5. Zooming in/out of web page from difference %, check UI display50%, 67%, 75%, 80%, 90%, 100%, 110%, 125% 150%, 175%, 200%(Chrome) 6. Check tips 17. Category: Fix Description: [153153] New Feature --21992 -- 09.01.01 -- [Kendo] Health status of task list is not complete when zoom in from 75% to 200% Impact motherboard: All X12/X13 platforms Affected functions: Task List Validation: 1. Login WEBUI -> Maintenance -> Task List 2. Zooming in/out of web page from difference %, check UI display 50%, 67%, 75%, 80%, 90%, 100%, 110%, 125% 150%, 175%, 200%(Chrome) 3. Check "Health Status" 18. Category: Fix Description: [153067] New Feature--18367--09.02.15(02/14/2023)--[Kendo]DDNS upload invalid key help tips is overlap when zooming to 200%. Impact motherboard: All X12/X13 platforms Affected functions: Dynamic DNS Validation: 1. Login BMC web GUI ->Go Configuration-> BMC Settings -> DDNS 2. Enable DDNS and Enable TSIG Authentication 3. Upload Invalid key with TSIG .key File and TSIG .private File For example: txt file 4. Zooming in/out of web page from difference %, check help tips 100%, 110%, 125%, 150%, 175%, 200% (Edge) 100%, 110%, 120%, 130%, 140%, 150%, 160%, 170%, 180%, 190%, 200% (Firefox) 5. Check error message 19. Category: Fix Description: [153097] New Feature --21992 -- 09.01.01 -- [Kendo] NTP server error message will exceed the fram and overlap with side bar when zoom in from 100% Impact motherboard: All X12/X13 platforms Affected functions: Date and Time Validation: 1. Login BMC web GUI-> Configuration -> BMC Settings -> Date and Time 2. Enable NTP 3. Enter invalid NTP server 4. Zooming in/out of web page from difference %, check UI display 50%, 67%, 75%, 80%, 90%, 100%, 110%, 125% 150%, 175%, 200%(Chrome) 5. Check error message 20. Category: Fix Description: [153113] New Feature --21992 -- 09.01.01 -- [Kendo] Upload invalid IPMI Configuration file help tips is overlap when zoom in to 200% Impact motherboard: All X13 platforms Affected functions: IPMI Configuration Validation: 1. Login BMC web GUI ->Go Configuration-> BMC Settings -> IPMI Configuration 2. Upload invalid file to "Reload IPMI Configuration" 3. Zooming in/out of web page from difference %, check UI display 50%, 67%, 75%, 80%, 90%, 100%, 110%, 125% 150%, 175%, 200%(Chrome) 4. Check tips 21. Category: Fix Description: [153069] New Feature --21992 -- 09.01.01 -- [Kendo] Power consumption is not complete when zooming from 110% Impact motherboard: All X13 platforms Affected functions: Dashboard Validation: 1. Login BMC web GUI -> Dashboard 2. Check Power Consumption 3. Zooming in/out of web page from difference %, check UI display 50%, 67%, 75%, 80%, 90%, 100%, 110%, 125% 150%, 175%, 200%(Chrome) 22. Category: Fix Description: [153012] New Feature--18367--09.02.15(02/14/2023)--[Kendo]Sensor thresholds columns should not hide when export to Excel file. [153005] New Feature--21992--09.02.15(02/14/2023)--[Kendo]Sensor thresholds is not complete/overlap/disappear when zooming from 100%. Impact motherboard: X12DPI-N6 Affected functions: Validation: 1.Go to [Sensor Reading] 2.Turn on Thresholds and check it with Zoom-in/Out page 3.Download excel file and check columns width 23. Category: Fix Description: [156797] ECO -- 16914 -- 01.01.43 -- [MEL] No related MEL when setup User with Account Type SNMP (Auth Protocol / Private Protocol) Impact motherboard: X12DHM Affected functions: Validation: 1.Login BMC web 2.Go to [User] page 3.Input SNMP related setting 24. Category: Fix Description: [157592] [IPMI ECO 1.01.43]Sensor naming not match with sensor specification Impact motherboard: X12DPG-QT Affected functions: Validation: 1. webGUI -> Sensor Readings. Observe the onboard M2 temeperature sensor naming. (cherry picked from commit 35c540e42aa60beb6b08b56f33242ad29dc75c03) 25. Category: Fix Description: [157592] [IPMI ECO 1.01.43]Sensor naming not match with sensor specification Impact motherboard: X12SPI Affected functions: Validation: 1. webGUI -> Sensor Readings. Observe the onboard M2 temeperature sensor naming. 26. Category: Fix Description: [150747] ECO --16914 -- 01.01.31 (12/09/2022) -- WEB -- Invalid Sensor name. Impact motherboard: X12SCZ Affected functions: Validation : 1. Login with ADMIN 2. System → Component Info → Sensor 3. Should match with SPEC. (cherry picked from commit e2baacfb4a63e214054c720d406a55e4da2a1b75) 27. Category: Enhancement Description: Remove static onboard LAN sensor to detect AOM card dynamically. Impact motherboard: H12DSG-Q Affected functions: Validation: 1. Update the BIOS to a version higher than 2.5 2. Use the "sdr list" command of ipmitool to check whether the original onboard LAN static sensor exists. 3. In the IPMI WEB, you can see the information and temperature of the AOM card on the "Network AOC" page. 28. Category: Fix Description: [157472] ECO -- 20899 -- 01.00.54 -- [GUI] SNMPv3 description in Help page is not aligned with web GUI Impact motherboard: X13DAi Affected functions: Validation: 1.Login BMC web 2.Open help page 3.Check wordings 29. Category: Fix Description: [157066] STD--SW--01.01.14-- Webgui crashed after uploading product key with invalid file Impact motherboard: X12DGO-6 Affected functions: Validation: 1. Go to Maintenance - License Activation page. 2. Select invalid file. 3. Show error message and disallow to click upload button. 30. Category: Fix Description: [156203] [IPMI ECO 01.00.18]Enable and Disable LDAP/Active Directory haven't record in MEL. [156493] ECO -- 21603 -- 01.00.18 -- No related MEL when enable LDAP and Active Directory (based on MEL SPEC v1.03) [152260] ECO --21603 -- 01.00.12 (01/17/2023) -- WEB -- MEL Log should be record when enable/disable LDAP/Active Directory. [152234] ECO -- 21386 -- 01.01.08 -- [MEL] No related MEL when setup Active Directory [151581] ECO -- 18379 -- 01.01.07 -- [MEL] No related MEL when setup Active Directory (either setup by SMCIPMITOOL) [151580] ECO -- 18379 -- 01.01.07 -- [MEL] No related MEL when setup LDAP (either setup by SMCIPMITOOL) [147072] ECO -- 16099 -- 00.23.70 -- No related MEL when setup Active Directory (either setup by SMCIPMITOOL) [146945] ECO -- 16416 -- 01.01.26 -- No related MEL when setup Active Directory (either setup by SMCIPMITOOL) [146888] ECO -- 16416 -- 01.01.26 -- No related MEL when setup LDAP (either setup by SMCIPMITOOL) [146736] ECO -- 16099 -- 00.23.68 -- No related MEL when setup LDAP (either setup by SMCIPMITOOL) [145792] ECO -- 16914 -- 01.01.28 -- No related MEL when setup Active Directory (either setup by SMCIPMITOOL) [145773] ECO -- 16914 -- 01.01.28 -- No related MEL when setup LDAP (either setup by SMCIPMITOOL) Impact motherboard: H13DSG, H13SSW, H13DSH, X13SET, H12DSG, X12SPG, X12SCZ, X12QCH, X12DPL Affected functions: Validation: 1.Login BMC web 2.Go to [Directory Service] page 3.Input related setting 4.Check MELs 31. Category: Fix Description: [156798] ECO -- 16914 -- 01.01.43 -- [MEL] MEL log not quite match when setup Alert SNMPv3 Authentication/ Encryption Protocol [156797] ECO -- 16914 -- 01.01.43 -- [MEL] No related MEL when setup User with Account Type SNMP (Auth Protocol / Private Protocol) [157272] ECO—16914—01.01.44 (05/12/2023)—[MEL] MEL log not quite match when setup Alert Redfish Protocol. [156499] ECO -- 21603 -- 01.00.18 -- [MEL] generated MEL not quite match when setup Alert SNMPv3 (based on MEL SPEC v1.03) Impact motherboard: X12DHM-6 H13DSG-O-CPU Affected functions: Validation: 1.Login BMC web 2.Go to [Alert] page 3.Input related setting 4.Check MELs 32. Category: Fix Description: [156577] ECO -- 21604 -- 01.00.18 -- [MEL] duplicate [MEL-0137] when setup SMTP Impact motherboard: H13DSG-O-CPU Affected functions: Validation: 1.Login BMC web 2.Go to [SMTP] page 3.Modify setting 4.Check MELs 33. Category: Fix Description: [156498] ECO -- 21603 -- 01.00.18 -- [MEL] should non-set IPv4 DNS Server IP related MEL be shown when setup IPv6 DNS Server IP or not Impact motherboard: H13DSG-O-CPU Affected functions: Validation: 1.Login BMC web 2.Go to [Network] page 3.Add then remove IPv6 DNS 4.Check MELs 34. Category: Fix Description: [151083] STD-01.00.05-SmartPower difference between SW/HW1 Impact motherboard: X13 Affected functions: Validation: 1.Login BMC web 2.Go to [Smart Power] page 3.Check the title wording 35. Category: New Description: [156694] RTX6000 ada GPU threshold is not correct Support RTX6000 ADA Impact motherboard: X12DAI Affected functions: Validation: 1. ipmitool sensor list. Observe the GPU temperature UC and UNR values. 36. Category: Fix Description: [156362] ECO -- 16914 -- 01.01.43 -- DIMM Sensor name Impact motherboard: X12SPED Affected functions: Validation: 1. webGUI -> Sensor Readings, check if sensor names meet spec. 37. Category: Fix Description: [156983] STD--SW--11.00.18-- Duplicate "Network AOC" on dashboard when system is in lockdown mode Impact motherboard: H13DSH Affected functions: Validation: 1. Go to Configuration - BMC Settings - System Lockdown page. 2. Turn on system lockdown and redirect to dashboard page. 3. Check Network AOC link should be only one. 38. Category: Fix Description: [156888] ECO -- 16914 -- 01.01.43(20230426) -- Sensor naming doesn't match the spec. Impact motherboard: X12SPO Affected functions: Validation: 1. webGUI -> Sensor Readings. Observe the sensor naming of DIMMA~D, DIMME~H, M2_SSD1, and M2_SSD2. (cherry picked from commit 4de29d90ca1434b8588d4ea1b7abdb4d6729a79c) 39. Category: New Description: [156694] RTX6000 ada GPU threshold is not correct Support RTX6000 ADA Impact motherboard: X12DAI Affected functions: Validation: 1. ipmitool sensor list. Observe the GPU temperature UC and UNR values. (cherry picked from commit f80eab511311a886059df8ed64ec89095c5aebfb) ============================================================================================================================== Filename: BMC_X12AST2600-ROT-5201MS_20230518_01.03.01_STDsp.bin version:01.03.01 BuildDate: 2023-05-18 U-Boot baseline : 2019.04 Java SOL Viewer version : v0.5.16 Java iKVM Viewer version : v1.69.52 Redfish API : Redfish_1_11_API_full_list_20230320 TEE Package dateCode: 20210911 pooh.ko: 3.0.5 tee.bin: 0000.00.29 antiRBID: 0x0001 Supported MBs: X12DPI-6, X12DPU-6, X12DDW-A6, X12DPG-QT6, X12DHM, X12DPFR-AN6, X12DAI-N6, X12DPG-AR6, X12DPG-U6, X12DPL-I6, X12DSC-A6 X12SPW-TF/-F, X12SPi-TF, X12SPO-F/-NTF, X12SPZ-SPLN6F, X12SPM-TF/-LN4F/-LN6TF, X12SPL-F/-LN4F, X12SPED-F, X12DPG-QBT6 1. Category: Enhancement Description: Support both CDC-ECM and RNDIS at the same time. Impact motherboard: All X12/X13 Affected functions: Validation: 1. Check with the command "dmesg | usb" 2. For the Linux which does not support RNDIS driver, host OS will identify the host interface as a CDC-ECM device. 2. Category: New Features Description: [299 Phase 1] Disable IPMI Lan Port Interface Impact motherboard: All MBs Affected functions: Validation: 1. User can decide whether to disable UDP 623 port and service. 2. SOL feature and other tools will be affected, when UDP 623 port is disable 3. By default, UDP 623 port is enabled for IPMI LAN. 3. Category: New Features Description: [299 Phase 1] Disable IPMI Lan Port Interface Impact motherboard: All MBs Affected functions: Validation: 1. User can decide whether to disable UDP 623 port and service. 2. SOL feature and other tools will be affected, when UDP 623 port is disable 3. By default, UDP 623 port is enabled for IPMI LAN. 4. Category: Enhancement Description: [299][MultVM] Virtual media support 3 CD/FLOPPY image mounting Impact motherboard: All MBs Affected functions: Validation: 1. Support at most 3 CD/FLOPPY image mounting at the same time by Redfish and WebUI (SPEC: https://wiki.supermicro.com/index.php/NS_SWPM:SW_PM/Functional_SPEC/Virtual_Media) 5. Category: Enhancement Description: [299][MultVM] Virtual media support 3 CD/FLOPPY image mounting Impact motherboard: All MBs Affected functions: Validation: 1. Support at most 3 CD/FLOPPY image mounting at the same time by Redfish and WebUI (SPEC: https://wiki.supermicro.com/index.php/NS_SWPM:SW_PM/Functional_SPEC/Virtual_Media) 6. Category: Enhancement Description: [Enhancement][Account Services][LDAP] Support StartTLS. Impact motherboard: * All X12/H12 MBs that support LDAP. Affected functions: Validation: 1. WebGUI -> Account Service -> LDAP. 2. Enable StartTLS and add/modify the setting of LDAP server that supports StartTLS 3. Log out of BMC web. 4. Log in BMC web with the account created by LDAP server. 5. Check if user can log in BMC web successfully or not. 7. Category: Enhancement Description: [299 Phase 1] HTML5 Console as default Impact motherboard: All MBs Affected functions: Validation: 1. HTML5 Console as default 8. Category: Enhancement Description: [299 Phase 1] Dual mode for network setting as default Impact motherboard: All MBs Affected functions: Validation: 1. Dual mode for network setting as default 9. Category: Enhancement Description: [Enhancement] Modify Dedicated Link options: Add 1G Full and remove 10M Half/Full execept X12STD-F and X12STE-F. * X12STD-F Dedicated Link is fixed in Auto Negotiation. * X12STE-F Dedicated Link is fixed in 1G Full. Impact motherboard: * All X12/H12 MBs Affected functions: Validation: 1. WebGUI -> Configuration -> Network. 2. Check if Dedicated Link options are correct or not. 3. Change Lan Interface to Dedicated and change Dedicated Link option you want. 4. Click Save button. 5. Check if Dedicated Status/Speed/Duplex are correct or not.